Solenoid SI Series
Features:
- Allows temporary isolation of house loads from engine circuit during engine cranking to protect sensitive electronics
- Automatically combines battery banks during the charging cycle and isolates under discharge
- 12/24 Volt auto ranging voltage input
- Waterproof rated IP67 - temporary immersion for 30 minutes
- Ignition protected - safe for installation aboard gasoline powered boats
- Remote LED output indicates relay state away from ACR
- Supports high-output alternators up to 120 Amperes
- Automatically combines battery banks during the charging cycle and isolates under discharge
- Ignition protected - safe for installation aboard gasoline-powered boats
- Activates from any charging source - alternators, battery chargers, or solar panels
Specifications:
- Continuous rating: 120A DC
- Intermittent rating: 210A DC
- Closed current draw:
175mA @ 12 Volts 115 mA @ 24 Volts - Open current draw: 15mA
- Opening delay: 0.34 seconds
- Relay contact position - Combine (30seconds):
13.6V DC @ 12 V 27.2V DC @ 24V - Relay contact position - Combine (2 minutes):
13.0V DC @ 12V 26.0V DC @ 24V - Relay contact position - Open Low (30 seconds):
12.75V DC @ 12V 25.5V DC @ 24V - Relay contact position - Open Low (10 seconds):
12.35V DC @ 12V 24.7V DC @ 24V - Relay contact position - Open High:
16.0V DC @ 12V 30.0V DC @ 24V - Terminal stud size: 3/8"-16 (accepts M10 ring terminal)
- Maximum cable size: 1/0 AWG
- Maximum torque: 140lb
- Agency standards ISO 8846
- Meets SAE J1171 external ignition protection requirements - rated IP67
- Weight: 0.57kg (1.26lb)
- Width: 98.71mm (3.886")
- Height: 88.96mm (3.502")
|
|
|
|
|
|